Hwatime XM750 Patient Monitor
Product Description
Material: Plastic
Quality Certification: CE&ISO
Instrument classification: Class II
ECG Lead mode: 3-lead or 5-lead
ECG Waveform: 4-lead, dual-channel 3-lead, single-channel
NIBP Mode: Manual, Auto, STAT
Color: White
Application: OR/ICU/NICU/PICU
Packaging & Delivery:
Packaging Details
One main unit Patient monitor, one NIBP cuff and tube, one Spo2 sensor, one ECG Cable, one ground cable and Disposable ECG Electrodes.
Product packaging size (length, width, height): 330*315*350MM/410*280*360MM
GW: 4.5KG/5.5KG
Delivery Port: Shenzhen, Guangdong
Product Description
Product name | XM550/XM750 Multi Parameter Monitor |
Functions | Standard parameters: ECG, NIBP, RESP, PR, SpO2, Dual-channel TEMP |
Optional Functions | EtCO2, Dual-IBP, 12-Leads ECG, Touch Screen, Built-in thermal printer |
Multi-languages | Chinese, English, French, Turkish, Spanish, Portuguese, Italian |
Product feature | Standard parameters: ECG, NIBP, RESP, PR, SpO2, TEMP |
Colorful and Clear 10/12.1’’ color screen, Backlight buttons | |
Multiple display modes optional:Standard interface, Large font, ECG standard full display, OXY, Trend table, BP trend, View-bed | |
Ambulatory blood pressure technology, anti-movement | |
Special design against high frequency surgical unit, and defibrillation protection | |
Support Masimo SpO2-authorization partner | |
13 kinds of arrhythmic analysis | |
15 kinds of drug dose calculation | |
Various languages operating systems | |
Built-in detachable rechargeable lithium battery 4 hours battery life | |
To connect CMS, other bed observation and software updating with wireless and wired mode | |
Data & Storage | stable and fast |
8000 groups NIBP measurements | |
680 hours Trend data and Trend graphs | |
200 groups Alarm events reviewing | |
2hours Wave forms reviewing | |
Alarming | Alarms refer to visual and audible indications triggered by a vital sign that appears abnormal or by technical problem of the patient monitor. |
Alarm type | |
Physiological alarms | |
Physiological alarms are triggered by a monitored parameter value that exceeds set alarm limits or an abnormal patient physiological condition. Physiological alarms are displayed in the physiological alarm area. | |
Technical alarms | |
Technical alarms are triggered by the monitor or application part malfunction. Technical alarms are displayed in the technical alarm area. | |
safe and reliable | |
3 level audible and visual alarming | |
Dual alarm light for physiological and technical alarming | |
Battery | The monitor is equipped with a rechargeable battery. The battery in the Monitor can automatically recharge when connected to AC input until it is full. A symbol is displayed in the upper right corner of the screen to indicate the state of recharging. |
Battery power can only last for a while. When the battery is about to run out, the monitor will trigger high level technical alarm “BATTERY TOO LOW”. At this moment, please connect the monitor to AC power and charge the battery immediately. Otherwise, the monitor will automatically power off after about 5 minutes. |